Technical features
- Maximum working pressure (PS): 50-450 bar
- Test pressure (PT): PS x 1,43 / 1,3 / 1,5
- Body: in AISI 316L stainless steel
- Bladder: NBR, HNBR, EPDM, FPM, HYTREL, Butyl, Polyurethane
- Installation position: horizontal / vertical (nitrogen valve upward)
Compression ratio:
- recommended: P2/P0 = 2.5
- maximum: P2/P0 = 4
Mechanical life: the number of cycles is inversely proportional to the increase of the compression ratio. For pulsation dampener applications, the nitrogen value must be from 60% to 80% of the working pressure also in relation with the type of pump and the working temperature
Also available:
- Outside epoxy painted as per standard FOX procedure or as project specification
- Connection with flange SAE 3000 – SAE 6000, ANSI B16.5 or UNI/DIN
- Connection API spec. 6A type 6BX
- Autoclave or Grayloc connection
- Special connection on request
- Integral flange connection
- Maintenance Free (HBX-SMF)
- Exotic material execution